APPLICATIONS

  • COMPONENTS PARTS TESTING
  • INSERTION LOSS TESTING

  • SHIELDING EFFECTIVENSS TESTING

Looking for something a little more customized? No problem. Genisco has the expertise to listen to your needs, then customize any of our filters to your exact specifications — and deliver them with the same timeliness and quality that we are famous for.

POPULAR CUSTOMIZATION OPTIONS

Special Features

  • Enclosed terminations
  • Multi-circuit
  • Manufactured and tested per the applicable portions of MIL-PRF-15733
  • Hermetically sealed with welded and soldered seams for shielding effectiveness
  • Standard Current Ratings: 5AMP to 250 AMP
  • Bleeder resistors incorporated to eliminate potential shock hazard

Functional Characteristics

  • Voltage Rating: 100 Vdc, 120/208 Vac, (50/60, 400 Hz)277/480 Vac, (50/60 Hz)
  • Voltage Drop: 2% maximum at full rated unity power factor load
  • Temperature Rating: per MIL-PRF-15733
  • Current Overload: 140% maximum current rating per MIL-PRF-15733
  • Dielectric With-Standing Voltage: per MIL-PRF-15733
  • Insulation Resistance: MIL-PRF-15733 (w/o discharge ckts)

Applicable Characteristics

  • MIL-PRF-15733: General specifications for filters, military
  • MIL-STD-202: Test methods for components parts, military
  • MIL-STD-220A: Test methods for insertion loss, military
  • MIL-STD-285: Test method for shielding effectiveness
  • NFPA 70/2011: National Electrical Code, standards

Looking for something a little more customized? No problem. Genisco has the expertise to listen to your needs, then customize any of our filters to your exact specifications — and deliver them with the same timeliness and quality that we are famous for.

POPULAR CUSTOMIZATION OPTIONS

Special Features

  • Enclosed terminations
  • Multi-circuit
  • Manufactured and tested per the applicable portions of MIL-PRF-15733
  • Hermetically sealed with welded and soldered seams for shielding effectiveness
  • Standard Current Ratings: 5AMP to 250 AMP
  • Bleeder resistors incorporated to eliminate potential shock hazard

Functional Characteristics

  • Voltage Rating: 100 Vdc, 120/208 Vac, (50/60, 400 Hz)277/480 Vac, (50/60 Hz)
  • Voltage Drop: 2% maximum at full rated unity power factor load
  • Temperature Rating: per MIL-PRF-15733
  • Current Overload: 140% maximum current rating per MIL-PRF-15733
  • Dielectric With-Standing Voltage: per MIL-PRF-15733
  • Insulation Resistance: MIL-PRF-15733 (w/o discharge ckts)

Applicable Characteristics

  • MIL-PRF-15733: General specifications for filters, military
  • MIL-STD-202: Test methods for components parts, military
  • MIL-STD-220A: Test methods for insertion loss, military
  • MIL-STD-285: Test method for shielding effectiveness
  • NFPA 70/2011: National Electrical Code, standards