Power Line Filters
Stand Alone Wall Mount
Power filters protect and facilitate power and secure communications for shielded rooms and buildings.
Download Product Data Sheet: GF67940 Data Sheet


SPECIAL FEATURES
Filters
- Factory pre-wired clean output lead provided through the pipe penetration
- Low Pass filter circuits ~ passive components which include inductors, capacitors, resistors, and optional transient suppression devices
- Manufactured and tested per applicable portions of MIL-PRF-15733
- All circuits provided in a single enclosure
- Discharge resistors incorporated to eliminate potential shock hazard
Enclosures
- Fabricated case of not less than 18 gauge cold rolled steel electro plated or painted Gray (Std. Paint Color)
- Sealed with welded and soldered seams for minimum shielding effectiveness 100 dB, 14 kHz to 18 GHz
- Threaded steel pipe penetration
- Double knock outs provided on filter case input
- Front cover access to input terminals
- Mounting tab provided for easy wall mount options
FUNCTIONAL CHARACTERISTICS
- Voltage Ratings:
- 24-1,000 VDC
- 120/208 VAC (50/60 Hz)
- 277/480 VAC (50/60 Hz)
- Voltage Drop:
- 2% maximum at full rated unity power factor load.
- Harmonic Distortion:
- 4% maximum at full rated unity power factor load
- Temperature Rating:
- MIL-PRF-15733
- Current Overload:
- 140% maximum current rating
- RF Radiation:
- Greater than 100 dB isolation
- Dielectric With-Standing Voltage:
- 2,200 VDC (prior to installation of discharge resistors)
- Insulation Resistance:
- MIL-PRF-15733 (prior to installation of discharge resistors)
- Insertion loss:
- 100 dB 14 KHz to 18 GHz
- 50/50 Ohm System
APPLICABLE SPECIFICATIONS
- Military Specifications
- MIL-PRF-15733 General
- Military Test Methods
- MIL-STD-202 Component Parts
- MIL-STD-220 Insertion Loss
- MIL-STD-285 Shielding Effectiveness
- NFPA 70/2011 National Electrical Code Standards
AVAILABLE OPTIONS
- MOVs – EMP and Surge Suppression
- Alternate pipe penetration locations on the enclosure available by request
- Voltage Indicator Lights
- Ground Wire
- Internal Mounting Flange